Thermo Mass Photo / TG-DTA/MS

SIMULTANEOUS THERMAL ANALYSIS AND MASS SPECTROMETRY

Thermo Mass Photo combines simultaneous thermal analysis with mass spectrometry. This technique is suitable for the qualitative analysis of evolved gases coincident with the STA signal.

Measures the evolved gases associated with weight changes and endothermic or exothermic reaction

Features

  • Detection over a mass range from hydrogen to m/z 410 with high sensitivity
  • Detection of unexpectedly evolved gas with high sensitivity
  • Available with two ionizations: electron ionization (EI) and photoionization (PI)
  • Integrated model of STA and MS coupled with the skimmer-type interface
  • User-friendly software: simple measurement controlled by a single software and versatile analysis with 3D presentation of MS
  • Measuring temperature range
  • Standard model : Ambient to 1000°C
  • High-temperature model : Ambient to 1500°C

Overview

Thermo Mass Photo/S is a simultaneous measurement system in which a skimmer type gas introduction interface and a soft ionization (photoionization) technique are integrated in a combination system of thermogravimetric-differential thermal analyzer and mass spectrometer. Measurements are carried out by heating the sample. The TG-DTA measures the thermogravimetric (TG) change and the thermal difference (DTA), while the evolved gaseous products are analyzed by the quadrupole mass spectrometer (QMS) which is injected towards the QMS consisting of a gas injection system.

Combining the fragment less soft-ionization technique and the ideal skimmer-type gas interface to measure the masses of the evolved gases with high accuracy, the gases are analyzed in real time even when multicomponent gases are generated simultaneously. The evolved gas analysis coupled with TG-DTA and QMS can be measured from room temperature to 1,000°C.

Improved performance and safe measurement

Combining the differential balance control and the horizontal triple-coil balance system improves the measurement stability of TG baseline and S/N ratio enabling a high sensitive measurement compared to the conventional type.

Aside from the temperature control method derived from the conventional temperature control program, high resolution thermal analysis is possible using the controlled rate thermal analysis (dynamic controlled method) because the heating rate is automatically controlled depending on the physical changes of the sample.

It is equipped with 2 different modes, namely electron ionization (EI) and soft ionization by photoionization (PI), which are available with just one-click on the software, suitable for qualitative analysis of evolved gases.

  • Skimmer-type interface

Since it adopts the skimmer type interface which is composed of a double orifice structure based on the jet separator principle, we have achieved a more compact design than the conventional capillary method.

  • Photo Ionization (PI)

The soft ionization method using VUV (vacuum ultraviolet) lamp enables ionization of molecular ions suppressing fragmentation. Through this, we can confirm the molecular ions (parent ions) in a fragment-free spectrum.

Since the conventional electron ionization is installed, by comparing the EI and PI results, we can obtain a more detailed evolved gas analysis result

Safety and easy maintenance

The system is designed for the user’s safety in which the furnace is inaccessible when the temperature is high and the ease of replacing the sample holders and the skimmer interfaces.

Safety and easy maintenance

The system is designed for the user’s safety in which the furnace is inaccessible when the temperature is high and the ease of replacing the sample holders and the skimmer interfaces.

User-friendly analysis software

The TG-DTA measurement result can be processed in a detailed data analysis using the standard analysis software. Moreover, multiplots of TG, DTA, temperature, and the mass spectral data (MS thermogram) can be displayed in real-time as well as after measurement. Since it is installed with an ASCII conversion software as a standard, the mass spectral data and the thermal analysis data can be easily utilized in other software.

Dynamic TG measurement

Thermo Mass Photo/S provides the two modes of dynamic TG measurement as a standard as well as the “Thermogravimetric and Differential Thermal Analyzer TG-DTA”,

Stepwise isothermal control (SIA) method

Constant velocity reactive control (CRC) method

Specifications Table

Product name

Thermo Mass Photo

Technique

Simultaneous thermal analysis (STA) and mass spectrometry (MS)

Benefit

TG provides information on the weight changes derived from reactions such as dehydration, evaporation, sublimation, desorption, decomposition, adsorption, oxidation, while DTA provides temperature information associated with endo- or exothermic reactions.

Technology

Horizontal differential thermogravimetric-differential thermal analyzer (TG-DTA) w/ evolved gas analysis

Core attributes

Horizontal differential triple-coil balance system automatically cancels various fluctuations causing TG drift resulting to a more accurate measurement.

Core options

Smart loader

Computer

External PC

Core dimensions

870 (W) x 576 (H) x 547 (D) (mm)

 

Application Note

Analysis of a mixture of gases for simultaneous
Characterizing the thermal degradation of polymer
Comparison of drugs
Determination of compounding ratio for complex material, Nylon
Evaluation amount of water in flour, drug and polymer
Evaluation of chocolates
Evolved gas analysis for volatile organic compounds
Evolved gas analysis of PEFC electrolyte membrane in humidity atmosphere