Winner3009
Automatic Wide Range Dry Laser Particle Size Analyzer

The Winner3009 Intelligent Dry Laser Particle Size Analyzer uses compressed air for dispersion and supports both manual and fully automatic operation modes. Based on the Mie scattering principle, it features a converging light Fourier transform optical path, a highly stable He-Ne laser, and a high-sensitivity ring photoelectric detector. These advanced components ensure excellent repeatability and high measurement accuracy, making it ideal for precise dry particle analysis.
Overview
The Winner3009 is an advanced dry laser particle size analyzer that supports both manual and fully automatic operation modes. Built on the Mie scattering principle, it incorporates a converging light Fourier transform optical path, a highly stable He-Ne laser, and a high-sensitivity ring photoelectric detector, all of which ensure outstanding repeatability and measurement accuracy.
Utilizing air as the dispersion medium, the system employs the turbulent dispersion principle in combination with a high-precision feeding device, a patented powder spray pump, and an oil-free silent gas source. These features ensure that samples are fully and uniformly dispersed, even for challenging dry powders.
The Winner3009 is ideally suited for all types of dry powder materials, particularly those that react with water or change shape when in liquid, making it an excellent alternative to wet laser particle size analyzers. Despite the dry dispersion method, it offers comparable accuracy and repeatability to wet systems.
Main Specifications
Model | Winner3009 | |
Standard | ISO 13320-1:2009;GB/T19077.1-2016;Q/0100JWN001-2020 | |
Measuring Range | 0.1-2000μm | |
Channels Number | 100 | |
Accuracy | <0.5% (Deviation of D50 on national standard sample) | |
Repeatability | <0.5% (Deviation of D50 on national standard sample ) | |
Light source | He-Ne laser (λ= 632.8nm, P>2.0MW) | |
Dispersion | Dry-turbulence dispersion mode, normal shock wave shear technique | |
Operation Mode | Manual & Full automatic | |
Operation temperature | +5°C to +40°C | |
Feeding | Automatic vibration feeding | |
Optical Calibration System | Automatic | |
Software function | Analysis mode | Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. |
Statistic Method | Volume Distribution, Quantity Distribution | |
Statistic Comparison | Several Testing Results of samplesDifferent batches of samples testing result,Samples before and after processing, Test result of samples in different time. | |
User-defined Analysis | Figure out percentage according to the particle sizeFigure out particle size according to the percentageFigure out percentage according to the particle size rangeMeet demands of representation of particle test in different industries | |
Test Report | Word, Excel,Photo( Bmp), Text etc | |
Multi-language Support | Multi-language Support | |
Intelligent operation | Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor | |
Test Speed | <1min for each time | |
Power supply | 220V | |
Volume | L105cm×W44cm×H54cm | |
Net Weight | 58Kg |
Overview
1) Advanced Optical Path Design
Utilizing Winner’s patented Converging Light Fourier Transform Technology, the system eliminates limitations caused by lens aperture. A combination of main detectors and large-angle auxiliary detectors ensures comprehensive collection of scattered light across all angles, resulting in high testing accuracy and reliability throughout the full measurement range.
2) Scientific Dispersion System
The patented turbulent dispersion technology, combined with the normal shock shearing effect, ensures that particles are thoroughly and uniformly dispersed. The use of wear-resistant ceramic components significantly extends the lifespan of the dispersion system.
3) User-Friendly Operation
Supports both manual and fully automatic operation modes, offering flexibility and ease of use depending on the user’s preferences and testing requirements.
4) High-Precision Automatic Optical Path Calibration
Equipped with a four-phase hybrid stepper motor with micron-level inching precision, the system maintains optimal optical alignment at all times, ensuring stable and precise measurements.
5) Intelligent Data Analysis with Proprietary Software
Winner’s proprietary analysis software processes large volumes of particle data at high speed. Using unconstrained free-fitting technology, the system accurately reverses the particle size distribution and performs intelligent statistical analysis, ensuring high accuracy and repeatability of results.
6) Comprehensive Test Results
The system outputs not only standard particle size distribution curves, including D10, D50, and D90, but also supports custom analysis parameters, such as any particle diameter range from D0 to D100 and cumulative percentages above or below user-defined thresholds.
7) Customizable Reporting
Users can customize test reports and result display formats to align with specific industry standards and reporting requirements, offering maximum flexibility and professional presentation.
Application