Winner3006

Dry Laser Particle Size Analyzer

  • The Winner3006 is a versatile dry dispersion laser particle size analyzer that features an advanced structural design and a next-generation dispersion device, providing superior dispersion performance compared to similar instruments. Utilizing the Mie scattering theory as the core analytical principle, it incorporates a converging Fourier transform optical path, coupled with a highly stable He-Ne laser and high-sensitivity ring photodetectors, ensuring exceptional repeatability and accuracy of test results.


    Key Features:

    • Air as the Dispersion Medium: The turbulent dispersion principle is employed, along with a high-precision feeding apparatus and a patented powder injection pump. The no-oil silent air source ensures thorough and uniform dispersion of the sample.

    • Wide Application Range: The Winner3006 is suitable for any dry powder material, making it especially effective for powders that undergo chemical reactions in water or change shape in liquid.

    • Comparable Accuracy and Repeatability: Despite using a dry dispersion method, the Winner3006 delivers the same accuracy and repeatability as wet laser particle size analyzers, making it a reliable and efficient alternative.

Overview

The Winner3006 is a highly versatile dry dispersion laser particle size analyzer that features an advanced scientific structure design and a next-generation dispersion device, providing superior dispersion performance compared to similar instruments. Utilizing the Mie scattering theory as its theoretical foundation, the analyzer employs a converging Fourier transform optical path, coupled with a highly stable He-Ne laser and high-sensitivity ring photodetectors, ensuring exceptional repeatability and accuracy of the test results.


Key Features:

  • Efficient Dispersion System: The Winner3006 uses air as the dispersion medium and applies the turbulent dispersion principle. It features a high-precision feeding apparatus and a patented powder injection pump, combined with an oil-free silent air source to guarantee that the sample is thoroughly dispersed.

  • Wide Applicability: This instrument is suitable for all types of powder materials, and is especially effective for substances that undergo chemical reactions in water or experience shape changes when in liquid.

  • Comparable Accuracy to Wet Methods: Despite using dry dispersion, the Winner3006 delivers the same level of accuracy and repeatability as traditional wet laser particle size analyzers, offering a reliable alternative without the need for liquid mediums.

Main Specifications

Model Name

Winner3006

Standard

GB/T19077-2016;ISO 13320:2009;  Q/0100JWN001-2020

Size Range

0.1-600μm

Channels Number

98

Accuracy error

≤0.5%(Deviation of  D50 on national standard sample)

Repeatability error

≤0.5%(Deviation of  D50 on national standard sample)

Light Source

 High performance laser λ=639nm power p>2mW

Dispersion Method

Dry-turbulence dispersion mode

Operating mode

SOP can be set, one-click automatic test, automatic storage, automatic alignment and other functions

Test Speed

<1min/for each time

Volume

Host:1030*450*325mm

Dispersed modules:260*285*135mm

N.W

33Kg +7Kg

Overview

1) Unique Patent Technology for Optical Path and Detection System

The converging Fourier transform optical path technology overcomes the lens aperture limitations on the scattering angle, expanding the testing range in confined spaces. By integrating additional secondary photodetectors, the system effectively collects scattered light from all angles within the corresponding test range, ensuring high testing accuracy and reliable results across the entire measurement range.


2) Scientific and Automatic Dry Dispersion System

Utilizing patented turbulence dispersion technology and the normal shock shearing effect, particles are efficiently and thoroughly dispersed. The core dispersion system incorporates wear-resistant ceramics, which not only enhance the system’s durability but also ensure more accurate and stable testing results over time.


3) Convenient Vibration Feeding Control

The system allows for automatic vibration feeding speed adjustment, enabling one-click control of the feeding process for enhanced convenience and ease of use.


4) Intelligent Operation System for One-Key Testing

With the intelligent operation system, users simply place the sample in the analyzer, and the system automatically handles dust collection, air supply, feeding, and other tasks. This one-click operation minimizes user intervention, reduces workload, and eliminates human error, leading to improved testing accuracy and data authenticity.


5) Software Support with Unconstrained Free Fitting Technology

The analyzer’s unique unconstrained free fitting technology ensures that particle size analysis is not restricted by any functional limitations. This technology allows for an accurate representation of the particle distribution, guaranteeing the precision and reliability of the test results.


6) Advanced Data Analysis

  • Comprehensive Data Analysis: The software enables the calculation of various statistical parameters such as average particle size, D1-D100 range, surface area average, and volume average particle size, providing a complete overview of the sample’s particle size distribution.

  • Sample Grouping: The system allows for the creation of sample groups to easily store and compare test data from different periods, facilitating efficient data management and analysis.

Scheme:

Application

Applications of Winner3006 Dry Laser Particle Size Analyzer

The Winner3006 Dry Laser Particle Size Analyzer is widely used across various industries, including cement, ceramics, pharmaceuticals, dyes, pigments, fillers, chemical products, catalysts, coal dust, additives, pesticides, explosives, graphite, photographic materials, fuel, metal and non-metal powders, calcium carbonate, kaolin, and more.

It is particularly effective for materials that undergo chemical reactions, experience shape changes, or lose properties in liquid. Examples of such materials include herbs, magnetic materials, and powders with a wide distribution and larger particles. The Winner3006 is known for its unique applicability and practicality in analyzing these types of materials.

Patent Technologies

  • Optical Bench Design: Protected by Patent No. ZL 2014 2 0378380.8

  • Three-Dimensional Optical Bench Alignment System: Protected by Patent No. ZL 2013 2 0835882.4

  • MIE Scattering Principle Application: Protected by Patent No. ZL 2013 2 0812021.4

  • Full-Sealed Sample Cuvette for Dry Particle Size Analyzer: Protected by Patent No. ZL 2011 2 0267646.8

  • Powder Dispersion Pump Design: Protected by Patent No. ZL 2007 2 0018648.7

  • Winner-3006 Dry Laser Particle Size Analyzer

Tags

Particle Size Analyzer , dry standard laser particle size analyzer , particle size analysis , particle size analyzer cosmetic formulation , laser diffraction particle size analysis , test instruments , measuring the size of drops and pulve particles , gold analyzer , particle size analyze analyzer tester measurement , other test instruments