Winner2009

Auto Wet Dispersion Laser Particle Size Analyzer

  • The Winner2009 adopts the Mie scattering principle to deliver reliable and repeatable particle size analysis across a broad measurement range of 0.01μm to 2000μm (or 1200μm). Designed for versatility, it is suitable for a wide variety of applications across multiple industries.

    Equipped with a dual-beam and multi-spectral detection system along with side light scattering technology, the Winner2009 significantly enhances measurement precision, sensitivity, and overall performance, representing the leading edge of domestic technology in particle size analysis.

Overview

The Winner2009 Fully Automatic Wet Laser Particle Size Analyzer utilizes the Mie scattering principle to deliver accurate and repeatable particle size measurements over a wide range of 0.01μm to 2000μm (or 1200μm). Designed for diverse application needs, it provides reliable performance across various industries.

Featuring a dual-beam system, multi-spectral detection, and side light scattering technology, the Winner2009 significantly enhances testing precision and sensitivity. It stands as a representation of advanced domestic technology in the field of particle size analysis.

Main Specifications

Model Name

                    Winner2009A

                        Winner2009B

Standard

ISO13320-1:2009, GB/T19077.1-2016, Q/JWN001-2024

Principle

MIE scattering principle

Measuring Range

0.01μm-2000μm

0.01μm-1200μm

Channels Number

97

95 (different photo detectors & optical light path)

Accuracy error

<1%   (Deviation of  D50 on national standard sample)

Repeatability error

<1%   (Deviation of  D50 on national standard sample )

Light source

High performance He-Ne Laser (λ= 632.8nm,  P>2MW) Lifetime>25000hours

 

Dispersion

 Method

Ultrasonic

Frequency:40KHz   Power:35W,   Time: ≥1S ,Anti-dry function

Stir

Revolutions Speed: 0-3000RPM (Adjustable)

Circulate

Rated Flow:8L/min    Rated Power:10W

Sample Pool

Volume:350mL

Micro-Sample Pool

Volume: 10mL ( Available)

Operation Mode

Full automatic/ manual control, freely choose

Resolution

Free distribution truly reflect particle size distribution

Optical bench alignment system

Japan Canon lens, Full automatic,precision is up to 0.1um

Software  

function

Analysis mode

Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.

Statistic Method

Volume Distribution, Quantity Distribution

 

Statistic Comparison

Several Testing Results of samples

Different batches of samples testing result,

Samples before and after processing,

Test result of samples in different time.

 

User-defined Analysis

Figure out percentage according to the particle size

Figure out particle size according to the percentage

Figure out percentage according to the particle size range

Meet demands of representation of particle test in different industries

Test Report

Word, Excel,Photo( Bmp), Text etc

Multiple-language

 Support

Multiple language Support

Intelligent operation

 Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor

Testing speed

<2min/time

Outer dimension

1200mm*370mm*560mm  

Net weight

70 KG

Main Features:

Overview

1) Patented Optical Path Design

Winner’s patented optical path design utilizes converging light and Fourier transform techniques to overcome traditional aperture limitations, allowing scattered light to be fully captured. A dual-spectrum design enhances measurement precision across a wide range—from 0.01μm to 2000μm. Additionally, the orthogonal dual-laser setup, aided by a semiconductor auxiliary laser, expands the detection angle from 45° to 135°, ensuring comprehensive signal reception from all directions.


2) Expanded Particle Size Range

The Winner2008A features an extended measurement range down to 0.01μm, making it especially suitable for sub-micron particles. This advanced capability ensures results that meet international standards for fine particle analysis.


3) Fully Automated Built-in Wet Dispersion System

Integrated ultrasonic dispersion, mechanical stirring, and circulation pathways ensure uniform particle dispersion throughout testing. This built-in system avoids common issues such as uneven distribution or particle sedimentation associated with external dispersion setups, thus improving test accuracy.


4) Intelligent Operation Mode

With a smart automatic testing mode, users only need to add the sample and click “Test.” The instrument handles all subsequent processes—water supply, dispersion, circulation, testing, cleaning, data recording, analysis, saving, and printing—automatically. This reduces workload and eliminates human error, enhancing both accuracy and reliability.


5) Automatic Optical Path Alignment

Equipped with four hybrid stepper motors and a micro-precision of 0.1μm, the optical alignment system continuously optimizes the light path. This automation eliminates manual adjustments, ensuring stability and precision throughout testing.


6) Reliable Calibration Method

The system uses certified national standard materials for calibration across the entire measurement range. With simple procedures and a calibration frequency of just once per year, this ensures long-term reliability and ease of maintenance.


7) Proprietary Unconstrained Free-Fitting Technology

Winner’s unique unconstrained free-fitting patent technology enables particle size analysis without being limited by functional assumptions, providing a true reflection of the particle size distribution.

Ⅱ test analysis view

After testing, if necessary, to select records generated an average result, the system analyzes the formation of the recording. When the automatic mode test, without data processing, forming and maintaining a comprehensive system automatically analyzed test records.

Scheme:

Application

Tags

particle size analyzer supplier , Particle Size Analyzer , Laser Particle Size Analyzer , Particle Size Analyzer for Sale , Particle Size Analyzer Price , particle size distribution , malvern particle size analyzer , particle size , particle size test , particle size distribution