Winner2005A

Intelligent Laser Particle Size Analyzer

Winner2005 intelligent full automatic laser diffraction particle size analyzer with principle of Mie Scattering to precisely determine the particle size distribution from 0.μm1 to 1000μm. It enables you understand materials well, such as abrasives, adhesives

Winner2005 Intelligent Full-Automatic Laser Diffraction Particle Size Analyzer

The Winner2005 utilizes the Mie scattering principle to deliver high-precision particle size analysis across a wide range—from 0.1 µm to 1000 µm. Fully automatic in operation, it offers reliable, repeatable results that help industries deeply understand material characteristics and optimize processes.


Extensive Material Compatibility

The Winner2005 is designed to analyze particle size distribution in an exceptionally broad range of materials, including:

Industrial & Construction Materials

  • Cement, Ceramics, Refractory materials, Corundum, Dolomite, Barite, Plaster, Quartz, Kaolin, Silica, Talc, Tourmaline, Wollastonite, Zirconium Silicate, Zeolite

Pharmaceuticals & Healthcare

  • Active pharmaceutical ingredients (APIs), Excipients, Medicine, Cosmetics

Chemicals & Polymers

  • Catalysts, Resins, Polymers, Oxides, Petrochemicals, Synthetics, Emulsions

Coatings & Pigments

  • Paints, Pigments, Inks, Coatings, Fluorescent materials, Toners

Energy & Mining

  • Coal, Carbon Black, Metal Powders, Grinding media, Minerals

Food & Agriculture

  • Flour, Starch, Food Additives, Agrochemicals, Beverages

Environmental & Research

  • Soil sediments, Diatomite, Environmental monitoring samples

Electronics & Abrasives

  • Battery materials, Diamond powder, Boron carbide, Ferrite, Mica


Applications Across Industries

  • Abrasives

  • Adhesives

  • Batteries

  • Bubble materials

  • Chemicals & Petrochemicals

  • Coatings & Paints

  • Cosmetics

  • Environmental Science

  • Food & Beverage

  • Inks & Printing

  • Medical and Pharmaceutical R&D

  • Mining & Minerals

  • Paper & Packaging

  • Polymers & Plastics

  • Slurries & Suspensions


Whether for R&D laboratories or industrial quality control, Winner2005 is a powerful solution to meet modern particle characterization needs—accurate, automatic, and adaptable across materials and industries.

Main Specifications

Main Specifications:

Model NameWinner2005AWinner2005B
StandardISO13320-1:2009,GB/T19077.1-2016,Q/0100JWN001-2020
PrincipleMIE Scattering Principle
Size range0.01μm-1000μm0.1μm-1000μm
Photodetectos90 pcs69 pcs
Accuracy error<0.5% (Deviation of D50 on national standard sample)
Repeatability error<0.5% (Deviation of D50 on national standard sample)
LaserHigh performance He-Ne Laser λ= 632.8nm, p>2mWService time>25000 hour

Wet dispersion  

(Can be upgraded to solvent type)

UltrasonicFrequency:40KHz Power:35W, Time: ≥1S
AgitatorRevolutions Speed: 0-3000RPM (Adjustable)
CirculationRated Flow:8L/min Rated Power:10W
Sample tankVolume: 350mL
Operation modeManual and Full automatic
Optical alignment systemFull automatic optical path alignment system
Software functionAnalysis modeFree Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic MethodVolume Distribution, Quantity Distribution
Statistic ComparisonSeveral Testing Results of samplesDifferent batches of samples testing result,Samples before and after processing, Test result of samples in different time.
User-defined AnalysisFigure out percentage according to the particle sizeFigure out particle size according to the percentageFigure out percentage according to the particle size rangeMeet demands of representation of particle test in different industries
Test ReportWord, Excel,Photo( Bmp), Text etc
Multiple-language SupportMultiple language Support
Intelligent operationAutomatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
Testing speed<2min/time (including all the procedures) fastest measuring time<10S
Running temperature15 ℃ -35 ℃
Outer dimensionL85cm*W39cm*H45cm
Net weight40Kg

Overview

Main Features

1. Advanced Optical Path Design

Utilizing patented Fourier Transform Converging Light Technology, the Winner analyzer breaks through the limitations imposed by traditional Fourier lens apertures. By shortening the focal length and expanding the scattering angle range, it significantly enhances measurement resolution. The multi-element silicon photodiode ring ensures full capture of scattered light, leading to improved accuracy and reliability in particle detection.


2. Built-in Intelligent Liquid Dispersion System

The integrated design houses the stirring unit, ultrasonic dispersion system, and circulation path within the instrument. This configuration minimizes issues like uneven dispersion and large particle sedimentation often seen in externally piped systems, ensuring thorough and homogeneous particle dispersion every time.


3. Unconstrained Free-Fitting Software (Patent Technology)

Equipped with a proprietary data-fitting algorithm, the software analyzes scattering data without being restricted to predefined distribution models. This is essential for researchers needing to obtain accurate and real-world particle size distributions, especially for irregular or multi-modal samples.


4. Intelligent SOP-Controlled Measurement

The system allows users to perform entire test procedures with a single click from the PC. The Standard Operating Procedure (SOP) mode automates every step—from sample dispersion to data analysis—delivering precise and repeatable results in under 2 minutes.


5. User-Friendly Dual Operation Modes

Supports both manual and automatic testing. In manual mode, users can fine-tune parameters for unfamiliar or complex samples. Once conditions are optimized, automatic mode streamlines future testing for efficiency and consistency.


6. Three-Dimensional Automatic Optical Path Alignment

A precision-controlled hybrid stepping motor aligns the optical path in real-time, with an adjustment resolution of up to 0.1 µm. This eliminates the need for manual calibration, improving ease of use and ensuring stable, high-accuracy measurements.


7. Rapid Measurement Cycle

With all processes fully automated—water supply, ultrasonic dispersion, stirring, circulation, background check, sample testing, analysis, draining, and cleaning—the full particle analysis cycle is completed in less than 2 minutes.


8. Smart Data Processing

The system automatically filters out erroneous data and standardizes results for reporting. Manual intervention is not required, which ensures consistency and saves time in high-throughput testing environments.


Test Analysis Overview

Following each test, users can choose to aggregate multiple results and generate an average report. In automatic mode, all data is processed and saved in real-time without additional input. This creates a reliable, traceable record of test conditions and outcomes, ensuring comprehensive and accurate sample analysis.

Winner-2005 Intelligent Laser Particle Size Analyzer

Scheme:

Winner-2005 Intelligent Laser Particle Size Analyzer

Adopt Patents Technology:

● Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,

● Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.

● MIE scattering principle application patent No.- ZL 2013 2 0812021.4.

● Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0

● Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2

Application

Tags

Particle Size Analyzer Price , Particle Size Distribution Analyzer , Particle Size Analyzer , Laser Particle Size Analyzer , particle size distribution , wet particle size analyzer , Malvern Particle Analyzer , Particle Size Analyzer Price List , Portable Particle Size Analyzer , particle size analyzers